Alliance Laundry Systems PHM1397C User Manual

Page 31

Advertising
background image

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Specifications and Dimensions

29

F8112101

IMPORTANT: If the machines are to be mounted
less than 18 in. (457 mm) from each other or less
than 18 in. (457 mm) from a side wall, only the
inside bolt holes will be accessible. If the machines
are to be mounted less than 6 in. (152 mm) from
each other, a wall or other equipment, they must be
installed without using the skirt around the bottom,
as it cannot be reinstalled after the machines are in
place.

A bolt-locator fixture or rebar frame can be used as an
option for installation. This rigid welded assembly
made of reinforcing rod and mounting bolts is
designed to be embedded in concrete. Refer to Figure
12
.

PHM178N

1

Frame

2

Grout

Figure 11

1

2

2 in.

(51 mm)

8 in.

(203 mm)

0.75 in.

(19 mm)

PHM737N

1

Machine Base (1 in. [25.4 mm])

2

Mounting Bolt Threads

3

Grouting

4

Reinforcing Rod

Figure 12

PHM737N

1

2

3

4

Advertising