8 installation, 1 safety instructions 8.2 before installation, 8installation – Burkert Type 2301 User Manual

Page 22

Advertising
background image

22

Installation

8

insTallaTiOn

8.1

safety instructions

Danger!

danger – high pressure in the equipment!

▶ Before loosening the lines and valves, turn off the pressure and

vent the lines.

Warning!

risk of injury from improper installation!

▶ Installation may be carried out by authorised technicians only

and with the appropriate tools!

risk of injury from unintentional activation of the system and
an uncontrolled restart!

▶ Secure system from unintentional activation.

▶ Following assembly, ensure a controlled restart.
for control function i – danger if pilot pressure fails!
For control function I control and resetting occur pneumatically.
If the pressure fails, no defined position is reached.

▶ To ensure a controlled restart, first pressurize the device with

pilot pressure, then switch on the medium.

risk of injury from moving parts in the device!

▶ Do not reach into openings.

8.2

Before installation

• The globe control valve can be installed in any installation position,

preferably with the actuator in upright position.

• Before connecting the valve, ensure the pipelines are flush.
• Make certain the flow direction is correct (Flow direction always

below seat).

8.2.1 preparatory work

→

Clean pipelines (Sealing material, swarf, etc.).

devices with welded body
Remove the control unit from the actuator (if present):

→

Clamp the valve body in a holding device.

→

Loosen the fastening screws (2x).

→

Remove the control unit upwards.

Fastening screw
(2x)

Control unit

Actuator

Fig. 8: Disassembly the control unit