5 designated application area – Burkert Type 2301 User Manual

Page 9

Advertising
background image

9

Product description

5.4.2 Device versions

actuator sizes
Depending on the orifice, the globe control valve is available for the
following actuator sizes:

Orifice dn

available actuator size ø [mm]

4 - 15

50

70

-

-

20

50

70

25

50

70

90

32

-

90

130

40

90

130

50

90

130

65

-

130

80

130

100

130

Tab. 1: Actuator sizes

pilot pressure
Designs with lower pilot pressure (reduced spring force) are
available on request.
Contact your Bürkert sales office or our Sales Centre.
E-mail: [email protected]

5.5

Designated application area

Observe the maximum pressure range according to the
type label!

• Neutral gases and liquids up to 16 bar.
• Steam up to 11 bar absolute / 185 °C for seat seal steel / steel.

Steam up to 2.7 bar absolute / 130 °C for seat seal PTFE / steel.

• Aggressive media.

5.5.1 application areas

e.g.

Plant construction
Food processing
Chemical engineering
Sterilizer construction, temperature control
Gas dosing
Conveyor systems for various bulk material (also sensitive
foodstuff)

english

Type 2301

Advertising