Maintenance, cleaning

install the actuator (with control unit) on the valve body

→

Check the graphite seal and if required, replace it.

Warning!

danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen
applications there is a risk of an explosion!

▶ In specific applications, e.g. oxygen or analysis applications, use

appropriately authorised lubricants only.

→

Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).

note!

damage to the seat seal or the seat contour!

▶ When installing the actuator, ensure that the valve is in open

position.

→

control function a:
Without unit control: pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
With unit control: open the valve according to the operating
instructions for the control unit.

→

Screw actuator into the valve body.
Observe tightening torque (see “Tab. 15”).

1

2

Pilot air port

Fig. 31: Connections

tightening torques of valve body / nipples
dn

tightening torques [nm]

10/15

45 ±3

20

50 ±3

25

60 ±3

32

65 ±3

40
50

70 ±3

65

100 ±3

80

120 ±5

100

150 ±5

Tab. 15: Tightening torques of valve body / nipples

If the position of the pilot air ports for installation of the
hoses is unfavorable, these can be aligned steplessly by
rotating the actuator through 360°.
The procedure is described in the chapter entitled “8.3.4
Rotating the actuator”.