8625-2 Standard - 11
english
connection of temperature sensor PT 100
Temperature
sensor PT 100
Fig.: Connecting temperature sensor PT 100 to type 8625-2
1
(brown)
4 (black)
3 (blue)
Type 8625-2 temperature controller
M8 (3-pole)
ATTENTION!
Do not connect a voltage to pin 1 of the 3-pole plug! Pin 1
is a 0.5 mA output to supply the sensor (PT100)
1
2
Bridge pin 1 and pin 4 of
temperature controller directly at
the temperature sensor PT100 and
connect to pin 1 of PT100.
Connect pin 3 of temperature
controller to pin 2 of temperature
sensor PT100.
Advertising
See also other documents in the category Burkert Sensors:
- Type 1062 (112 pages)
- Type 1050 (4 pages)
- Type 8750 (64 pages)
- Type 8750 (82 pages)
- Type 8681 (40 pages)
- Type 8681 (90 pages)
- Type 8798 (106 pages)
- Type 8798 (2 pages)
- Type 8791 (4 pages)
- Type 8718 (34 pages)
- Type 8792 (118 pages)
- Type 8791 (15 pages)
- Type 8792 (136 pages)
- Type 8792 (252 pages)
- Type 8791 (28 pages)
- Type 8791 (21 pages)
- Type 8791 (154 pages)
- Type 8791 (106 pages)
- Type 8791 (184 pages)
- Type 0911 (76 pages)
- Type 0911 (46 pages)
- Type 0911 (64 pages)
- Type 0911 (84 pages)
- Type 1058 (31 pages)
- Type 1060 (4 pages)
- Type 1066 (112 pages)
- Type 1067 (158 pages)
- Type 1077-2 (33 pages)
- Type 1094 (12 pages)
- Type 1094 (41 pages)
- Type 1094 (82 pages)
- Type 1094 (126 pages)
- Type 1115 (25 pages)
- Type 1150 (99 pages)
- Type 1541 (2 pages)
- Type 5142 (6 pages)
- Type 8619 (40 pages)
- Type 8619 (134 pages)
- Type 8620 (177 pages)
- Type 8622 (4 pages)
- Type 8623 (130 pages)
- Type 8623 (90 pages)
- Type 8624 (124 pages)
- Type 8718 (254 pages)