Wiring

Type 8025/8035 /

→

Insert the cable clips: See "Fig. 21".

The wiring of the current output and the wiring of the pulse output of
the panel or wall-mounted transmitter, 12-36 V DC, without relays,
are the same as for a compact flowmeter, 12-36 V DC, with relays,
with cable glands.

→

Wire the current output according to "Fig. 27" of chap. "8.4.4".

→

Wire the pulse output according to "Fig. 28" of chap. "8.4.4".

8.7.

Wiring the 8025, wall-mounted
version, 115/230 V Ac, with or
without relays

8.7.1. Wiring instructions for a wall-

mounted version

Seal the unused cable gland using the stopper gasket sup-
plied to make sure the device is tight.

→

Unscrew the nut of the cable gland.

→

Remove the transparent disc inside the cable gland.

→

Insert the stopper gasket.

→

Screw the nut back.

→

Connect the flow sensor to the remote transmitter according to
chap. "8.5".

→

Configure the selectors on the electronic board: see chap. "8.3".

→

Loosen the nuts of the cable glands.

→

Insert each cable through a nut then through the cable gland, using
the cable glands as shown in "Fig. 39".

Flow sensor

cable

Cables of the outputs

Power supply cable,
12-36 V DC or
115/230 V AC

Fig. 39: Using the cable glands

→

Remove the two terminal blocks (marked 4 and 6 in "Fig. 40"
chap."8.7.2" and "Fig. 44" chap. "8.7.3") from the housing.

→

For the versions with relays, insert the cable clip. See "Fig. 21".

→

Depending on the version (with or without relays), wire the
device according to chap. "8.7.2" or "8.7.3".

→

Insert the two terminal blocks (marked 4 and 6 in "Fig. 40" chap.
"8.7.2" and "Fig. 44" chap. "8.7.3") into their original position.

→

Letting the housing stay completely open, secure the power
supply cable, the flow sensor connection cable and, depending
on the version, the relay connection cables, with the cable clips.

→

Tighten the cable glands making sure the cable in the housing is
long enough to allow complete opening of the housing.

→

Close the cover.

→

Tighten the 4 screws.

→