4. START-UP

IMPORTANT WARNINGS:

1. Before starting, check that the humidifier is in perfect condition, that there are no water leaks and that the electrical parts

are dry;

2. Do not connect power if the humidifier is damaged or even partially wet!


When installation is completed, flush the supply pipe for around 10 minutes by piping water directly into the drain, without sending it
into the humidifier; this will eliminate any scale or residues that may cause foam when boiling.

4.1 Startup

Checklist

Before starting the humidifier, the following should be checked:

• Water is connected (cold non-softened), the line has been flushed, and external valves are open.

• Drain is connected, run to an open drain, and has a trap under the unit.

• Electricity is connected in accordance with instructions, local codes and data labels in the unit.

• The power fuses are installed and intact.

• All control wiring is done and tested.

• Airflow switch is wired to open on air flow loss.

• Optional hi-limit humidistat is wired to open on humidity rise above set point.

• Unit wires have been checked to make sure they and all connectors are tight from shipping.

• The steam hose(s) are run correctly with no sags or kinks and sloped properly according to the manual.

• Condensate hoses are run correctly with no sags or kinks and sloped properly according to the manual.

4.2

The Elite Steam Controller

The Elite Steam controller features a comprehensive information display that shows the operation of the system at a glance:

1.

Display is % of nominal capacity

2. Maintenance

3.

Display is amperage (default)

4.

Steam is being produced

5. Cylinder

filling

6. Foaming
7.

Water presence inside the cylinder

8. Cylinder

draining

9.

LEDs indicate: power (yellow), operation (green) and alarms (red)

10.

Drain button for manual draining of cylinder and confirming
parameter values

11. ON/OFF

button

12.

Reset button to reset alarms and access parameters

13.

Level of output: 33%, 66%, 100%

14.

Fan relay is activated


The DS 50 / DS 50 LC is now ready to operate.

4.3

Starting the Elite Steam

• Insure that the external power is turned on.

• Push the top part of the On/Off button so that the I part is in. The yellow Power LED will

be lit. The Elite Steam is now ready to operate.

• When there is a call for humidity, DS 50 / DS 50 LC will close its power relays and send

power to the electrodes in the plastic steam generator. The green Operation LED will
light, indicating that operation has begun.

4.4

Starting with a new cylinder

When starting with a new cylinder, you should activate the cylinder cleaning function as follows:
1. Switch Elite Steam off.
2. Press and hold both buttons, “reset” and “drain”, and switch DS 50 / DS 50 LC back on.

When the wrench blinks

then release the two buttons.

3. Press and hold “reset” until the display shows 04.

WARNING: DO NOT confirm any value higher than 04. If 05 or higher is displayed,

press “reset” until the display goes back to the normal operating mode and restart from step

4. Press

drain” (minimum 1 second): the cleaning starts.

1

2

4

5

6

9

10

12

13

14

11

3

7

8