12

3.

Extended Diagnostics Mode (Viewable Only)

(Dy xx) Display Code xx = days since last Regeneration

— Press the Extra Cycle button once to advance to the next diagnostics.

(xxxx) No Display code xxxx = the volume used since the last Regeneration

— Press the Extra Cycle button once to Exit Extended Setup Programming Mode.

Control Programming Complete

Programming a Time Clock Regenerated System

1.

Regeneration Time (No Display Code)

The Regeneration Time display can be identified by observing a non-flashing colon between two sets of
numbers. Set the desired time of day that you want Regeneration to occur.

Example:

2 o'clock A.M. regeneration time: [ 2:00 ] (P.M. Indicator Dot Off)

— Use the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button to proceed to the next step.

2.

Regeneration Day (Display code A)

Use this display to set the number of days between Regeneration cycles. This setting is identified by
observing the letter "A" in the first digit. In the Time Clock regeneration mode, the system regenerates at the
time set in Step 1 on the programmed number of days.

Example:

Regeneration every 7 days [A -- 7]

— Use the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button once to Exit Setup Programming Mode or press and hold the Set Up and

Set Down buttons simultaneously for five (5) seconds to enter the extended setup programming mode.

Figure 11: Extended Diagnostics Mode

Figure 12: Regeneration Time

Figure 13: Regeneration Day