Model 7000, Troubleshooting, Error codes – Hydrotech 7000 Service Manual User Manual

Page 24: General troubleshooting

Advertising
background image

Model 7000

24

Troubleshooting

Error Codes

NOTE: Error Codes appear on the In Service display.

There are three possible error codes.:

General Troubleshooting

Error Code

Probable Cause

Recover and Resetting

( Err 0 )

Drive motor is stalled

Unplug the unit from the power source.
When power is restored to the unit, the Err _
display code clears. If the condition causing
the error has not been resolved the Err _
code reappears in the four digit display. Do
not attempt to troubleshoot this problem any
further. Contact the installer for service.

( Err 1 )

Drive motor is running continuously

( Err 2 )

There have been more than 99 days since
the last Regeneration

Regeneration must occur for the unit to
recover, the display to clear and the valve to
function normally. Contact the installer for
service.

WARNING

The controller MUST be depressurized before removing
any quick connection clips for servicing. The connector
should be pushed toward the control while removing clips.

PROBLEM

CAUSE

CORRECTION

1.

Softener fails to regenerate.

A. Electrical service to unit has been

interrupted.

B. Timer is defective.

A. Assure permanent electrical

service (check fuse, plug, pull
chain or switch).

B. Replace timer.

2. Hard water.

A. Bypass valve is open.

B. No salt in brine tank.

C. Injector screen plugged.

D. Insufficient water flowing into brine

tank.

E. Hot water tank hardness.

F. Leak at distributor tube.

G. Internal valve leak.

A. Close bypass valve.

B. Add Salt to brine tank and maintain

salt level above water level.

C. Clean injector screen.

D. Check brine tank fill time and clean

brine line flow control if plugged.

E. Repeated flushing of the hot water

tank is required.

F. Make sure distributor tube is not

cracked. Check O-Ring and tube
pilot.

B. Replace seals and spacers and/or

piston.