Model 7000 – Hydrotech 7000 Service Manual User Manual

Page 9

Advertising
background image

Model 7000

9

Programming a Meter Delayed Regenerated System

1.

Feed water hardness (Display Code H).

NOTE: The feed water hardness setting only displays when the system is set to operate as a Meter Immediate

or Meter Delayed system type.

— Press the Set Up or Set Down buttons to set the amount of feed water hardness in grains/gallon (U.S.) or

degrees (metric). The system automatically calculates treated water capacity based on the feed water
hardness and the system capacity preset in the Master Programming mode. "Calc" is displayed during
calculations.

Example:

Range: 4 – 199 U.S. and metric

— To program 9 grains / gallon (U.S.) or 9 degrees (metric) [ H - 9]

— Press the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button once to advance to the next step.

2.

Regeneration Time (No display Code)

NOTE: The Regeneration Time setting does not display in Meter Immediate Regeneration Mode since the

system regenerates immediately when the available capacity reaches zero (0).

Identify the Regeneration Time display by observing a non-flashing colon between two sets of numbers. Set
the desired time of day for Regeneration to occur.

Example:

2 o'clock A.M. regeneration time: [ 2:00 ] (P.M. Indicator Dot Off)

— Press the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button to exit the programming mode or press and hold the Set Up and Set Down

buttons simultaneously for five (5) seconds to enter the Extended Setup Programming Mode.

Figure 5: Feed Water Hardness

Figure 6: Regeneration Time

Advertising