Hydrotech Precision-PWS 45-75 OWNERS GUIDE User Manual
Page 6

3. Your distiller has been shipped with a sterilization drip tube that is to be placed between the cooling coil and the storage tank.
The tube end should be inserted into the storage tank properly. As your distiller continues to heat up, you can sterilize your
distiller by simply turning the fan switch off for approximately ½ to 1 hour. Leaving the storage tank lid on. After this cycle is
completed, turn the fan switch on and drain any excess water from the storage tank.
Caution: The Distiller will be extremely hot.
A) At this time, let the distiller cool down for approximately 1 hour. You may need to drain the water from the storage tank
with one of the drain nipples. Remove the sterilization drip tube by pulling the plastic tube off the stainless steel tube.
(Keep this tube, it will be needed to sterilize your distiller at a later date.)
B) Take the charcoal filter canister and remove the charcoal filter lid from the filter canister body and fill charcoal filter
canister 2/3 full.
C) Rinse charcoal with 2 cups of distilled water until water runs clear through filter.
D) Press filter lid onto filter body.
Figure 5
E) Lift up on corner of distiller and slide filter tube into tank and lower distiller so the cooling cool tube enters the top of
the filter. See Fig. 6.
Your distiller is now ready for years of service, please follow Operation, Maintenance and Cleaning instructions.
04/08/04
Page 6
'097045
Figure 6