ROUTINE MAINTENANCE

RECOMMENDATIONS

HAVE ALL COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE.

A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR SANITIZE THE SYSTEM.

(I.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS)

SERVICE REQUIREMENTS

To insure the system operates at its optimum level,

certain routine maintenance must be performed.

Frequency of maintenance performance will depend on

feed water quality and level of system usage.

CLEAN: Each time filters are replaced

SANITIZE: At least once every 12 months.

EQUIPMENT NEEDED

Safety glasses

Rubber gloves, sanitary

Wash Cloth, Clean and Lint-free

Household bleach - Unscented Only

(5 1/4% sodium hypochlorite)

Liquid dish soap

Plastic bucket, Plastic bowl

“O” Ring Lube FDA Approved

(P/N 30300026)

REPLACEMENT FILTER SETS

“O” RINGS

P/N 41400011 Carbon Filter, VOC Reduction (White Cap) - 1 each

P/N 41400010 Carbon Filter, Lead Reduction (Black Cap) - 3 each

P/N 34201010 Filter Cartridge

P/N 34201026 Filter Housing

CLEANING, SANITIZING, AND CARTRIDGE REPLACEMENT PROCEDURE


1. Mix a mild cleaning solution of dish soap and clean

potable water in the plastic bowl.


2. Shut feed water supply valve and open product water

faucet to relieve system pressure.


3. CAUTION: Do not attempt to remove filter housings

until water flow stops. This reduces pressure inside

the system so housings may be removed safely.

CAUTION: Additional point-of-use devices (i.e.,

icemakers) may use filters along their supply line.

Remove any filter or treatment device installed

between module and delivery device before

proceeding.

Remove each filter housing by turning it counter-

clockwise. Remove each filter cartridge as its housing

is removed. Discard filters.

Icemaker: Transfer ice cubes from bin/tray to clean

freezer container for storage until procedure is done.


4. CAUTION: Use sanitary rubber gloves for this

procedure to avoid contaminating sanitizing solution or

filters. Wear gloves whenever cleaning/ sanitizing

system components or handling new filter cartridges.

Remove filter housing "O" rings and wash them with

cleaning solution. Rinse them well with clean potable

water. Inspect the "O" rings for damage (i.e., nicks or

scratches). Replace damaged "O" rings.

5. CAUTION: Do not get the Smartap

®

Flow Monitor

electronics, wiring, or connectors wet.

Clean filter housings and manifold ports, inside and

outside with washcloth and cleaning solution. Do not

use abrasive materials.


6. Rinse housings/manifold with clean potable water.

7. Inspect manifold and filter housing "O" ring groove

area for damage (i.e., nicks or scratches). Replace

damaged

components.


8. Place a small amount of "O" ring lubricant over the

surface of the filter housing "O" ring. Install the "O" ring

into the filter housing groove.


TO SANITIZE SYSTEM: Complete Steps 9-29.

TO INSTALL FILTERS: Complete Steps 17-29.

WARNING: WEAR SAFETY GLASSES WHILE
PERFORMING THIS PROCEDURE.

WARNING: READ THE "WARNINGS" ON THE BLEACH
CONTAINER BEFORE USING.

WARNING: HANDLE SANITIZING SOLUTION
CAREFULLY. AVOID CONTACT WITH UNPROTECTED
AREAS.