Hydrotech 104 Series ADVANCED MULTI STAGE WATER TREATMENT SYSTEM User Manual

Page 9

Advertising
background image

- 5 -

PRODUCT WATER FAUCET INSTALLATION - STAINLESS STEEL OR CHROME FAUCET

Install faucet on flat surface at least 2" in diameter. Unused 1 1/4" hole is ideal.

Steps unique to a specific configuration are so noted. All other steps are common to either configuration.


New Faucet Installation

Refer to Faucet Site Preparation, Page 4.

Replacement Faucet Installation

Verify size of existing hole is 1 1/4".

NOTE: Item callouts refer to Page 6, Figure 7 unless
noted otherwise. Part numbers for each callout
are specified according to faucet type:

Chrome-Plated Faucets (brass faucet nipple):
Table A.

Stainless Steel Faucets (copper faucet nipple):
Tables B and C.

1. Push Button Smartap

: Verify faucet body, rubber

body washer, metal base washer, and rubber base
washer are in place above sink (Items 1, 12, 2 and 8).

Optional Faucet Smartap

: Verify faucet body,

rubber body washer, metal base washer, light bar
base washer, light bar assembly, and washboard
gasket are in place above sink (Items 1, 12, 2, 9, 10,
and 11).


2. Push Button Smartap

: Place faucet over hole.

Optional Faucet Smartap

: Insert monitor cord into

mounting hole and place faucet over hole.


3. CAUTION: Do not pinch, kink, or otherwise deform

monitor cord. Align cord with cutout in plastic spacer.


Push Button Smartap

: Install locating washer,

faucet washer, and nut on faucet nipple below sink
and snug them up (Items 7A, 6, and 5). Be sure to
align faucet properly before tightening. Do not over
tighten.


Optional Faucet Smartap

: Install slotted washer,

spacer, faucet washer, and nut on faucet nipple below
sink and snug them up (Items 7, 3, 6, and 5). Be sure
to align faucet properly before tightening. Do not over
tighten.

4. Install faucet connector (Item 4, packaged with faucet)

onto faucet nipple. Do not over tighten.


5. Install 3/8” blue tube into faucet connector.

6. CAUTION: Blue 3/8" tube connecting module to the

faucet must run with no sharp bends or loops (See

Page II, Figure 1).

Connect 3/8" blue tube to 3/8" swivel elbow located on
the rear of module.

7. Optional Faucet Smartap

: Connect monitor cord

to telephone-style connector located on manifold

cover (Figure 6).


8. The basic installation is complete and system is

ready for activation (see Page 10).

FROM

SMARTAP SERVICE

INDICATOR LIGHT


Figure 6

Connecting Monitor cord to Manifold.

Advertising