- 12 -

CLEANING, SANITIZING, AND CARTRIDGE REPLACEMENT

9. CAUTION: Excessive concentrations of bleach will

damage plastic and rubber components. Rinse all

parts that contact bleach thoroughly with clean potable

water.

Mix sanitizing solution of 1.5 ml (1/3 teaspoon) of

household bleach and 3.8 L (1 gallon) of clean,

potable water in the bucket. Mix the solution well.


10. CAUTION: Tighten filter housings by hand only.

Do not use tools as they will over-tighten and damage

housings. Take care not to cut or pinch “O” rings.

Add 236 ml (one cup or 8 oz.) of sanitizing solution to

each of the filter housings and install them onto the

manifold (do not install filters at this time). Tighten

each filter housing by hand only.


11. Slowly open the feed water supply valve.

12. Open product water faucet. Keep it open for 5

seconds after water starts coming out.


13. Close the product water faucet.

14. Wait 30 minutes, open product water faucet and let

water flow 5 minutes.


15. After 5 minutes, close feed water supply valve and

allow water to flow until system pressure is relieved.


16. CAUTION: Do not attempt to remove filter housings

until water flow stops. This reduces pressure inside

the system so housings may be removed safely.

Remove the filter housings and dispose of the water.

Rinse housings and manifold ports thoroughly with

clean potable water.


17. CAUTION: Do not remove protective plastic bag from

filters until so instructed.

Open the top of the bag only enough to expose

the top cap and "O" rings. Place a small amount of

“O” ring lubricant on surface of each “O” ring.

Install the filter cartridges. Hold cartridge by its

protective plastic bag and insert the cartridge into the

manifold turning it 1/2 turn as it enters the port (See

Page II, Figure 1 for location of each cartridge).

Slide bag from cartridge and discard it.

CAUTION: Tighten filter housings by hand only.

Do not use tools as they will over-tighten and damage

housings. Take care not to cut or pinch “O” rings.

Replace each filter housing as each cartridge is

installed.

NO WATER FLOW MONITOR:
Complete Steps 26 - 29

OPTIONAL SMARTAP

®

WATER FLOW MONITOR:

Complete Steps 18 – 29

Smartap

®

Flow Monitor Operation Requirements:


Monitor must be reset to zero each time system is serviced
and cartridges replaced. If monitor is not reset, there is no
way to determine when filters were changed or if the
system is still operating within specifications.

Monitor is reset when the battery (Item 24) is disconnected
from the clip. Failure to replace battery may result in
yellow light when system is reconnected.

Installing a new battery when filter cartridges are replaced
ensures an accurate indication of system performance and
a continuing supply of high quality drinking water.

18. CAUTION: The wiring within the module cover

connects the monitor components. If wires, circuit

board, or connections are damaged and/or wetted,

monitor will not function.

Loosen three mounting bracket screws. Gently pull

module cover up and away from module body.


19. Disconnect the battery. The connection to the battery

is a snap type connector (See Figure 11).


20. Remove the battery by sliding it out of its holder.

21. Replace the battery with a new alkaline 9-volt

transistor battery (P/N 31300001).


22. Carefully slide the battery into its holder.

23. CAUTION: Verify battery connector alignment before

making connection (Figure 11).

Reconnect the battery by pressing the clip onto the

battery

terminals.


24. Replace the module cover and tighten screws.

25. Turn feed water valve slowly to the open position.

26. Test battery connection by activating the monitor.

Pressing the test button or open the product water

faucet. If an indicator light illuminates, connection

is

good.

NOTE: Close faucet after light illuminates. Test

confirms connection, not system status.