INLET ADAPTER VALVE INSTALLATION

NOTE: This assembly is offered as an optional installation method. Make sure it is approved for use under
State and local plumbing codes before ordering kit (P/N 42500004).

NOTE: Use this assembly on U.S.N.P.T.* pipe thread fittings only.


1. CAUTION: If no shut off valve is installed under sink,

close main water valve during this installation.

Locate shut off valves on water lines under sink. To
identify hot supply pipe and cold supply pipe, turn both
faucets on and let water run. As water flows, hot water
pipe becomes noticeably warmer.


2. CAUTION: do not install feed water assembly on hot
water

line.

Turn off cold water supply by closing shut off valve.
Drain line by opening sink faucet. Some mixing type
faucets may also require turning off hot water supply.


NOTE: All item callouts refer to Figure 4 unless noted
otherwise.

3. CAUTION: Place container or towel below shut-off

valve to catch any water remaining in pipe.

Disconnect cold water supply line to sink at inlet valve
end of line.


4. Insert rubber washer (Item 1) into inlet adapter

(Item 2) and install adapter onto supply valve.

Align outlet hole (in side of adapter) toward location

of RO Module.


5. Replace existing rubber grommet on cold water

supply line with grommet supplied in kit (Item 3).


6. CAUTION: Use thread-sealing tape (P/N 35700002)

on male threaded connections in Steps 4, 6, 7, and 8.

Attach cold water supply line to inlet adapter.


7. Install ball valve (Item 4) into inlet adapter.

8. Install male connector (Item 5) into inlet ball valve.

9. Install ¼” white tubing (Item 6) from male connector to

filtration module inlet elbow (Item 7 on Page 9,

Figure

10).


10. Close inlet valve by turning handle so it is at a right

angle (90º) to valve body.


11. CAUTION: Do not open valve until system is

activated (Page 10).

Turn on cold water supply. Check installation for leaks.
Allow water to run from faucet for a few minutes to
clear any debris in the supply line caused

by this installation.

NOTE: If flow from faucet is reduced, clean faucet
aerator.

Item

Description

Part No.

Inlet Assembly

1 Rubber

Washer

33400002

2

Inlet Adapter 1/2" x 1/2" x 1/8"

33201001

3 Rubber

Grommet

33400003

4

Inlet Ball Valve 1/8"

34900002

5

Male Connector 1/4" x 1/8" NPT*

33503301

Component of Installation Kit

#6

#5

#4

#1

EXISTING COLD WATER
SUPPLY VALVE

COLD WATER LINE

TO SINK

#2

#3

6

Tubing, 1/4" White

20300014

* United States National Pipe Thread


Figure 4

Inlet Adapter Assembly P/N 42500004 Installation and Parts Breakdown

Advertising