Prepare the sampler, Clean the sample bottles, Install a single bottle – Hach-Lange SD900 Refrigerated Sampler, SD900 AWRS User Manual User Manual
Page 12: Clean the sample bottles install a single bottle
• The refrigerated sampler must be installed in an indoor location. The AWRS can be installed in an
outdoor location.
• Make sure that the temperature at the site location is within the specifications.
• Install the sampler on a level surface. Adjust the sampler feet to make the sampler level.
• Use the installed anchor brackets and user-supplied
3
/
8
-in. bolts for the AWRS. Refer to
.
• Plumb a drain tube to the ½ in.-14 NPT female connector on the bottom of the sampler.
Figure 3 AWRS anchor bracket locations with mounting dimensions
1 Optional anchor brackets
2 Anchor brackets (2x)
Prepare the sampler
Clean the sample bottles
Clean the sample bottles and caps with a brush, water and a mild detergent. Flush the containers
with fresh water followed by a distilled water rinse.
Install a single bottle
Use a single bottle to collect one composite sample. When the bottle is full, the full bottle shut-off
stops the sample program.
1. Clean the sample bottles. Refer to
2. Install the sample bottle as shown in
.
10 English