IMPORTANT SAFETY NOTES

INITIATION

92809 3 07/13

MAGNETIC FIELDS

<< The machine may not be operated by more

than one person at any given time!

The machine was designed for safe operation

by “one person only”.

<< During the degaussing process no other

work may be performed on the machine

(for example cleaning, etc.)!

<< The unti is not a toy, and is not suitable

for use by children!

The overall technical safety concept of this

machine does not provide for any guarantee

regarding hazard-free operation by children.

<< Persons with pacemakers must not work

at the unit before having consulted their at-

tending doctor or physiotherapist! Danger

of heart rhythm disturbances due to stray

magnetic fields!

<< In case of danger switch the machine off

with the mains switch, or with the emer-

gency switch, or unplug the unit!

<< Always unplug the machine from the mains

power supply before opening the machine!

Repairs may only be performed by trained

personnel!

Power Supply:

95~105, 105~115, 115~125, 215~225, 225~235 or 235~240, 50/60Hz

Is pre-set in accordance with the respective site of operation.

Power Consumption:

100V:

Under Standby 0.3A While charging 5.0A At the time of ERASE 0.6A

110V:

Under Standby 0.25A While charging 4.5A At the time of ERASE 0.55A

120V:

Under Standby 0.2A While charging 4.0A At the time of ERASE 0.5A

220V:

Under Standby 0.17A While charging 2.5A At the time of ERASE 0.35A

230V:

Under Standby 0.16A While charging 2.25A At the time of ERASE 0.325A

240V:

Under Standby 0.15A While charging 2.0A At the time of ERASE 0.3A

Degausser System:

Capacitive Discharge

Operating Time, Duty Cycle:

Continuous

Erasing time:

< 15 milliseconds

Cycle time:

45 seconds per cycle.

Magnetic Field:

20.000 Oe measured in center.

Max. Media Size:

108mm (4.25 in.)(W) x 31.5mm (1.25 in.)(H) x 149mm (5.86 in.)(D)

Erasing Area Size:

108mm (4.25 in.)(W) x 31.5mm (1.25 in.)(H) x 149mm (5.86 in.)(D)

Media:

2.5 type HDD, 3.5 type HDD, DLT, LTO, 3490 and more

Temperature:

5°C - 40°C (41°F - 104°F)

Humidity:

10%H - 40%H (without condensation)

Weight machine:

65.5 kg (144 lbs.)

Weight shipping:

83.6 kg (184 lbs.)

Size machine:

54cm (21.5 in.)(L) x 44cm (17.5 in.)(W) x 47.5cm (19 in.)(H)

Size shipping:

82.5cm (33 in.)(L) x 62.5cm (25 in.)(W) x 77.5cm (31 in.)(H)

Warranty:

2 Years Factory Warranty Standard

TECHNICAL DATA

DISPOSING OF THE MACHINE:

Dispose of the machine in an

environmentally sound fashion at the

end of its useful service life. Do not

dispose of any of the parts included

in the machine or its packaging with

household trash.

DISPOSING

MAGNETIC FIELDS MEASURED AROUND PERIMETER

The

intimus 20000 produces a single focused magnetic pulse lasting less than 1/20 of a second.

The focused intensity allows the unit to erase today’s highest coercivity media while also limiting the

magnetic field exposure to 1 second for every 20 pieces of media degaussed.

Distance from

Magnetic field

Magnetic field

Duration of Field

degausser

front side

side

0 cm (0”)

1320 gauss

68 gauss

< 0,05 Second

10 cm (4”)

440 gauss

22 gauss

< 0,05 Second

20 cm (8”)

145 gauss

8 gauss

< 0,05 Second

30 cm (12”)

49 gauss

3 gauss

< 0,05 Second

Note: The testing room measured 0.4 gauss before degausser was plugged in.

Average Operational Distance (AOD) from user to the degausser is 12-18 inches (30-45cm). According

to the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values

(2005) - Static Magnetic Fields, whole body exposure limits recommended for an 8 hour shift are

600 gauss. Because of the short duration of each pulse from an degausser (1/20

th

* of a second) and

the extremely small magnetic field outside of the unit (<49 gauss, AOD) the total 8 hour whole body

exposure is 0,008% of the recommended limit.

* Pulse duration was rounded to ½ second per discharge for calculations to cover any build up of magnetic fields

generated before or after discharge.

INTRODUCTION

The degausser Model

intimus 20000 is a conti-

nuous duty capacitive discharge degausser. The

unit is designed to erase hard drives and tape

cartridges that fit inside the drawer. The conveni-

ent media loading design accommodates many

different types and sizes of media, without the

need for adapters.

INSPECTION

Inspect the degausser for shipping damage as

soon as it is unpacked. If the degausser or any

accessories are damaged or fail to operate cor-

rectly, notify carrier and contact your dealer im-

mediately.

INSTALLATION

Power Plug

Plug the IEC connector attached to the power

cord supplied into the receptacle on the back of

the unit.

Fuse Block

Always unplug the unit from the mains

power supply before opening the

machine! Changes in power supply

may only be performed by trained

personnel!

Located behind the removable panel on the front

side of the unit, there are six separate fuses, one

each for 100, 110, 120, 220, 230 & 240 VAC po-

wer. Only one fuse is used at a time. Therefore,

for any voltage range, the two unused fuses of

the same value can be used as spares.

Location

The degausser must be placed on a flat, hard

surface. Keep at least a 15 cm (6 inch) distance

from any object that may interfere with the coo-

ling fan exhaust located on the backside of the

degausser. As a general rule, media not inten-

ding to be erased should be kept about 60 cm

(2 ft) away.

Cooling

Forced air-cooling is used to maintain safe ope-

rating temperatures within the degausser. The

air intake and exhaust through the holesis are

located on the back panel. To ensure proper

cooling, do not block the air-intake and maintain

at least a 15 cm (6“) distance from the back of

the degausser to any obstacle.