 EN • 13

SMARTPASS LAMP ERROR INDICATION

2

1

4

3

ExPLANATION

RECOMMENDATION

Service battery overheated

Check condition and/or installation

Too high current through or temperature

at internal relay. Too high Service bat-

tery charge current.

Check service battery. Reduce alternator size or

add one more D250S DUAL in parallel. Service bat-

tery bank too deeply discharged.

Too high current through or temperature

at internal relay. Too many consumers

connected at the same time.

Consider relocation of unit. Reduce power usage.

Too high current through or temperature

at internal relay. Too high current to

starter battery.

Starter battery problems, check battery.

Too high current through or temperature

at internal relay. Too many consumers

connected.

Relocate unit or reduce concurrent use of consumers.

Battery watch activated. Service battery

too low

Recharge Service battery

Steady lamp