 EN • 19

SITUATION

One alternator and a Solar panel feed-

ing a Starter battery and a small Service

battery.

PROBLEM

The Service battery will take a very long

time to recharge due to low alternator

voltage. The Solar panel is difficult to

synchronize with the alternator. Due to

these issues, the battery will underper-

form and die prematurely.

SOLUTION

The D250S Dual charges the Service

battery quickly and very efficiently

from both the Alternator and the Solar

panel. The Solar panel produces at its

maximum power point when the engine

is off. When both the Solar panel and

the Alternator are on, the Solar panel

adjusts to the Alternator. The battery will

be fully charged, produce more and last

significantly longer.

TIP 4

See Tip 1 and Tip 2.

INSTALLATION ShEET 4

SOLAR PANEL

WARNING!

D250S DUAL is not reverse

polarity protected

WARNING!

•Max 23 V input

•Do not connect two solar panels in series

D250S DUAL

12V

+OUT

+IN

+IN