STEP 1 DESULFATION

Detects sulfated batteries. Pulsing current and voltage, removes

sulfate from the lead plates of the battery restoring battery

capacity.

STEP 2 BULK

Charging with maximum current until approximately 80 % bat-

tery capacity.

STEP 3 ABSORPTION

Charging with declining current to maximize up to 100 % bat-

tery capacity.

STEP 4 FLOAT

Maintaining the battery voltage at maximum level by providing

a constant voltage charge.

STEP 5 PULSE

Maintaining the battery at 95–100 % capacity. The charger

monitors the battery voltage and gives a pulse when necessary

to keep the battery fully charged.

1

PULSE

DESULPHATION

BULK

ABSORPTION

1

4

2

3

FLOAT

5

VOLTAGE (V)

CURRENT (A)

ChARGING PROGRAM D250S DUAL

The charger starts charging the target battery when the supply voltage exceeds 13.1 V for 5 sec (engine on).

The charger stops charging the target battery when the supply voltage drops below 12.8 V for 10 sec (engine off).