• BGU-D Barrier Gate Operator Installation Guide

- 9 -

P558 Revision X13 8-11-2011

Terminal Descriptions

TERMINAL

GROUP

FUNCTION

AC N

24 VOLT INPUT

FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR
24 VDC FROM CONTINUOUS DUTY DC SUPPLY.

AC

DC -

ACCESSORY POWER

PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX)

DC +

RESET

RESET BUTTON

NOT USED IN BARRIER GATES.

COMMON

C

COMM LINK

FOR 3-WIRE NETWORK CONNECTION TO SECOND OPERATOR IN DUAL GATE INSTALLATIONS.

B

A

COMMON

SINGLE BUTTON INPUT

CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES
BETWEEN OPEN-CLOSE OR OPEN-STOP-CLOSE DEPENDING ON PROGRAMMING.

SINGLE

COMMON

FIRE BOX INPUT

CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPARTMENT ACCESS.

FIRE DEPT

COMMON

OPEN INPUT

CONNECT TO NORMALLY OPEN DEVICES (KEYPAD, CARD READER,
KEYSWITCH, TELEPHONE ENTRY SYSTEM) TO OPEN THE GATE. A CONSTANT
OPEN INPUT WILL HALT THE AUTO CLOSE TIMER UNTIL RELEASED.

OPEN

OPEN

3-BUTTON
STATION INPUT

CONNECT TO 3-BUTTON STATION FOR OPEN-CLOSE-STOP CONTROL. A CONSTANT OPEN INPUT
WILL OVERRIDE THE MID-TRAVEL STOP AND HALT THE AUTO CLOSE TIMER UNTIL RELEASED.

CLOSE

COMMON

STOP

COM

OPEN/RESET
INPUT

PROGRAMMABLE FOR STANDARD RESET LOOP, OPEN COUNTER MODE USING
THE SHADOW/RESET LOOP, OR OPEN SUPERVISED MODE. SEE PAGE 15.

OPEN/RESET

C-OBS

CLOSE
OBSTRUCTION
INPUT

CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN
OBSTRUCTION DURING CLOSING. WHILE GATE IS MOVING, ANY CLOSE OBSTRUCTION
SIGNAL WILL CAUSE THE GATE TO STOP, THEN REVERSE AND TRAVEL TO THE FULL
OPEN POSITION. SHOULD A OPEN OBSTRUCTION INPUT OR AN OPEN DIRECTION
INHERENT ENTRAPMENT CONDITION OCCUR PRIOR TO THE GATE REACHING THE
OPEN LIMIT, THE OPERATOR WILL LOCKOUT AND SOUND THE CONTINUOUS TONE
ALARM. IF THE AUTO CLOSE TIMER IS SET, WHEN THE CLOSE OBSTRUCTION INPUT
IS CLEARED, THE GATE WILL CLOSE WHEN THE AUTO CLOSE TIMER EXPIRES.

COM

COM

REVERSE

CONNECT TO NORMALLY OPEN DEVICES TO CAUSE A REVERSAL WHEN
THE GATE IS TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL
OPEN POSITION. TYPICALLY NOT USED IN BARRIER GATES.

REV

OPEN LOOP

OPEN LOOP

CONNECT TO OPEN LOOP/FREE EXIT LOOP. THE GATE WILL OPEN
WHEN THE LOOP IS TRIGGERED, AND REMAIN OPEN AS LONG AS
THE LOOP IS TRIGGERED. REQUIRES LOOP DETECTOR.

OPEN LOOP

REVERSE LOOP

REVERSE LOOP

CONNECT TO REVERSE LOOP. TRIGGERING THE LOOP WILL CAUSE A REVERSAL
WHEN THE GATE IS TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN
POSITION. REQUIRES LOOP DETECTOR. TYPICALLY NOT USED IN BARRIER GATES.

REVERSE LOOP

SHADOW/RESET LOOP

SHADOW/RESET LOOP

CONNECT TO RESET LOOP TO KEEP THE GATE IN ITS FULLY OPEN POSITION AS LONG AS
THE SIGNAL IS PRESENT. USED TO KEEP GATE OPEN WHILE VEHICLE IS PASSING THROUGH.
REQUIRES LOOP DETECTOR. ALSO USED FOR OPEN COUNTER MODE IN BARRIER GATES.

SHADOW/RESET LOOP

-

ALARM

NOT USED IN BARRIER GATES.

+

N.O.

AUX RELAY

FOR CONNECTION TO AUXILIARY DEVICES (MAGNETIC LOCK, SOLENOID LOCK,
STROBE LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION.

COM

N.C.

+

24 VOLT SOLAR PANEL

FOR CONNECTION TO 24 VOLT SOLAR PANEL FOR BATTERY CHARGING.

-

+

24 VOLT BATTERY

FACTORY CONNECTED TO BATTERIES IN DC MODEL OPERATORS.

-