Warning, Model bgu and bgu-d maintenance, Preventative maintenance – Controlled Products Systems Group BGU-12-311 User Manual

Page 27: Fcc notice

Advertising
background image

BGU

• BGU-D Barrier Gate Operator Installation Guide

- 25 -

P558 Revision X13 8-11-2011

Model BGU and BGU-D Maintenance

Battery Maintenance

The gel-cell batteries in this operator require no routine
maintenance. For assured continued performance, they
should be replaced every year. If power is to be removed
for one week or more, disconnect the negative wire from the
batteries as this will prevent deep discharging. Fully charge
before use after storage or upon initial installation.

Preventative Maintenance

General

Linear gate operators are designed for many years of
trouble-free operation and, under recommended operating
conditions, will require only minimal maintenance. To ensure
that a unit is ready for operation at all times, and to preclude
serious damage or failure, inspect the unit systematically.
Proper adjustments and lubrication should be made as
recommended.

Lubrication

Bearings — For models which have pillow block style

bearings with grease fi ttings, lubricate at least twice a
year with a lithium complex based, petroleum oil NLGI 2
rated grease. Oilite and precision sealed bearings do not
require additional lubrication.

Motor — Motors have sealed ball bearings and do not

require further lubrication. If bearing noise develops after
several years of operation, bearings should be replaced
by a motor repair company, or the motor should be
replaced if necessary.

Barrier Gate Arm — Check all bolts for proper tension

and tighten if necessary. If the arm has been warped or
damaged, replace as necessary.

6-Month Preventative Maintenance

1. For operators which utilize torque limiting clutches,

check for proper tightness. If there appears to be dust
from wear on the pads, inspect the pads and replace
if necessary. If the clutch cannot be adjusted tightly
enough to move the gate without slipping, the pads must
be replaced.

2. For operators with V-belts, inspect for wear and replace

as necessary. Check for proper tension and adjust if
required. Check all pulley setscrews for tightness and
tighten if necessary.

3. For operators with internal chain drives, inspect chain

and sprockets for wear and replace if necessary. Check
for proper tension and alignment, and adjust if required.
Check all hub sprocket setscrews and tighten if required.

4. Check limit switches and limit actuators (cams, limit nuts,

etc.) for wear and replace as required. In rotary limit
switch assemblies, wipe the limit shaft clean and apply a
light coating of dry lubricant.

5. Inspect all nuts and bolts for proper tightness and tighten

as necessary.

6. Check all reversing devices for proper function. Inspect

all contact edges for wear and replace if required. Check
photoeyes for proper alignment and function.

7. Check current sensing for proper adjustment when

fi nished with inspection and maintenance.

8. Inspect the installation area. Are all the warning signs

intact and visible? If they are missing or need replacing,
contact Linear. Be sure there are no control stations
mounted within reach of the gate. Review safety literature
with the customer and advise them to remove any such
stations found.

FCC Notice

This device complies with FCC Rules Part 15 and Industry
Canada Rules & Regulations. Operation is subject to the
following two conditions: (1) This device may not cause
harmful interference and (2) this device must accept any
interference received, including interference that may cause
undesired operation.

WARNING

Always disconnect power from operator before servicing.
Keep clear of gate during operation.

Advertising
This manual is related to the following products: