Installation on Concrete Curb

The barrier gate operator bolts to a concrete island or curb.

1. Un-crate the gate. Avoid damaging the cabinet fi nish.

2. Leave the machine bolted to the bottom pallet until ready to install.

3. Open the cabinet door.

4. Remove the bolts holding the gate to its pallet and place the machine

in position on the curb. Refer to your Equipment Layout (EL) drawing
for proper positioning of your gate.

5. With a pencil, mark the location of the mounting holes on the concrete.

6. Set the gate aside. Drill all four mounting holes using a 3/4” diameter

rotary hammer percussion drill bit. Insert lag screw anchors for 1/2”
lag bolts. Place the gate back in position, and anchor it with 1/2” lag
bolts and fl at washers. Lubricate the bolts before installation. Flat
washers have been supplied to go between pavement and cabinet.
Linear highly recommends using the corner mounting holes when
mounting barrier gates.

7. Proceed with the rest of the installation process.

36"

ISLAND

WIDTH

36"

24"

12"

18"

4" DIA. GUARD POSTS
4 FT. TALL, BY OTHERS

15"

7-1/2"

6-1/4"

4-3/4"

4-3/4"

6-1/4"

6-1/4"

6-1/4"

7-1/2"

15"

.75 ø 8X

OPEN SPACE FOR

CONDUITS HERE

SERVICE DOOR SIDE
OF BARRIER GATE
(FACES AWAY FROM DRIVE)

Figure 1. Concrete Lag Anchor Detail

Figure 2. Barrier Gate Mounting Specifi cations

WARNING

The operator is intended for installation only on gates used for
vehicles. Pedestrians must be supplied with a separate access
opening. The pedestrian access opening shall be designed to
promote pedestrian usage. Locate the gate such that persons
will not come into contact with the vehicular gate during the
entire path of travel of the vehicular gate.

WARNING

The gate must be installed in a location so that enough
clearance is supplied between the gate and adjacent
structures when opening and closing to reduce the risk of
entrapment.

CABINET BASE

1/2

ø

X4" LAG BOLT

AND FLAT WASHER

SUPPLIED
FLAT WASHER

3/4ø HOLE
IN CONCRETE

LAG SCREW
ANCHOR