Advanced controller programming (cont.), Single button input setup, Stagger mode – Controlled Products Systems Group BGU-12-311 User Manual

Page 15: Stagger delay time, Auxiliary relay mode, Reverse delay time

Advertising
background image

BGU

• BGU-D Barrier Gate Operator Installation Guide

- 13 -

P558 Revision X13 8-11-2011

Advanced Controller Programming (Cont.)

Single Button Input Setup

This function is used for selecting the operation for single button controls
and radio receivers.

The factory default sets the SINGLE input terminal so successive inputs
will cycle the operator in OPEN-STOP-CLOSE-STOP order.

Alternately, the SINGLE input can be set to cause the gate to OPEN
unless the gate is fully open. If the gate is closing, the input will cause
the gate to reverse. If the gate is fully open, the input will cause the gate
to CLOSE.

Stagger Mode

This function is not used in dual barrier gate installations.

NOTE: This function will only be displayed if dual

gate operation is selected.

Stagger Delay Time

This function is not used in dual barrier gate installations.

NOTE: This function will only be displayed if dual

gate operation is selected.

Auxiliary Relay Mode

The Auxiliary Relay has normally open and normally closed contacts.
The factory setting disables the Auxiliary Relay. The relay can be set for:

• Maglock: To deactivate a magnetic or solenoid gate lock, the relay

will energize during any pending or actual gate motion (open only).

• M4: To deactivate a magnetic or solenoid gate lock, the relay will

energize during any pending or actual gate motion (open only).
3 seconds after the gate starts to move, the relay will de-energize.
This option is used for higher current solenoid locks.

• Ticket

Dispenser: The relay will energize while the gate is moving

in the open direction and at the full open limit, or in an entrapment
condition.

• Strobe: To activate a warning strobe light, the relay will energize

during any pending or actual gate motion (either open or close).

• Alarm: The relay will energize if the gate is manually forced open

from the full closed position.

Reverse Delay Time

The factory default sets the Reverse Delay to 0 seconds. The operator
will wait the length of the delay before reversing direction. This feature
will not change the reversal time when the operator is responding to an
entrapment condition from an obstruction input or inherent entrapment
protection sensor. The Reverse Delay can be set from 0 to 9 seconds.
Heaver gates require a longer delay to allow time for the gate to stop.
The Reverse Delay is active when the gate fi rst stops on either limit or in
between limits.

FUNCTION

SINGLE INPUT WILL OPEN OPERATOR,
IF OPERATOR IS ALREADY OPEN, SINGLE
INPUT WILL CLOSE OPERATOR

SINGLE INPUT WILL CYCLE OPERATOR
IN ORDER OF OPEN-STOP-CLOSE-STOP

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

SINGLE BUTTON

INPUT SETUP

"SB"

FUNCTION

"SM"

FUNCTION

"ST"

FUNCTION

AUXILIARY RELAY USED FOR
MAGLOCK CONTROL

AUXILIARY RELAY DISABLED

AUXILIARY RELAY USED FOR
TICKET DISPENSER CONTROL

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

AUXILIARY

RELAY MODE

"AR"

AUXILIARY RELAY USED FOR
WARNING STROBE LIGHT

AUXILIARY RELAY USED FOR
CONNECTION TO ALARM DEVICE

AUXILIARY RELAY USED FOR
MAGLOCK OR SOLENOID CONTROL
3 SECOND DELAY TO RE-ENERGIZE

FUNCTION

SET TIMER VALUE
0 TO 9 SECONDS

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

REVERSE

DELAY TIME

"RD"