3.1.12 Keypad

Function

This programming sequence sets the function of the 0 through 9, and the # keys on the keypad
during conversation. The keys can be set to hang-up the entry system when they are pressed during
conversation, or they can be programmed to DTMF tone out during conversation. The later may be
desirable if the entry system is used with an auto-attendant type telephone system where the caller is
prompted to enter numbers from a touch-tone telephone. HINT: If DTMF tones are required, program
the # or * key to hang-up the system.

Factory setting = 0 for all numbers (hang-up).

1.

Press *26 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the desired key number _ then press * (beep).

3.

Press 0* (beep) for hang-up, or press 1* (beep) for touch-tone.

4.

Repeat steps 2 and 3 to program other keys.

5.

Press 0# TOGETHER to end this programming step (beeeeeep).


3.1.13 System to Stay On-Line or Hang Up after Touch Tone

This programming sequence provides a method for the telephone entry system to remain on line after
a resident has pressed the touch tone number to open the door or gate. Each relay can be set
independently to either remain on line or hang up.

Factory setting = 1 (hang up after touch tone) for both relays.

1.

Press *28 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Press 1* for relay 1 (beep), or press 2* for relay 2 (beep).

3.

Press 0* (beep) to keep the system on line, or press 1* (beep) to make it hang up.

4.

Repeat steps 2 and 3 to program the other relay.

5.

Press 0# TOGETHER to end this programming step (beeeeeep).

3.1.14 Automatic Hang-up Function

This programming sequence determines when the phone system will automatically hang itself up
after a predetermined time of inactivity. You can program the system to not hang-up (0), to hang-up
after 5 sec of dial-tone (1), to hang-up after 15 sec of silence (2) or to hang-up after either 5 sec of
dial-tone or 15 sec of silence (3). NOTE: This programming function is available on REV G
boards or higher only.

Factory setting = 1 (hang-up after 5 sec of dial-tone).

1.

Press *40 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the hang-up code desired _ then press * (beep).

3.

Press 0# TOGETHER to end this programming step (beeeeeep).

Code Function

0 No

hang-up.

1

Hang-up after 5 sec. of dial-tone (Factory setting).

2

Hang-up after 15 sec. of silence.

3

Hang-up after 5 sec. of dial-tone OR 15 sec. of silence.