2.2

Wiring Diagram

DOORKING, INC., INGLEWOOD, CA 90301

Title:

Date:

Rev.

Dwg. No.

PWR

INPUT

1

Phone

Line

5

6

4

7

1

2

NO NC COM

MAIN TERMINAL

RELAY 2 CONTACTS

SWITCH 2
INPUT

Strike /

Mag Lck

Gate

Operator

Lock

Pwr

3

2

Gate

Operator

Strike /

Mag Lck

Lock

Pwr

2

3

Field Wire Diagram - 1862 Control Board

9/03

A

M1800-065-11

Phone Line Wiring Max Distance

800 Feet

1600 Feet

24 AWG

22 AWG

Power Wiring Max Distance

100 Feet

200 Feet

18 AWG

16 AWG

16 Volt, 20 VA UL Listed power transformer.

1

2

Power for door strikes or magnetic lock is not provided by the
system. It must be provided by an external power supply.

3

Electric strikes are wired to Normally Open (N.O.) contacts; magnetic
locks are wired to the Normally Closed (N.C.) contacts.

4

Optional 12 Volt gel cell for backup power.

5

Dedicated Central Office (C.O.) phone line - touch tone, loop start.

6

A switch closure across terminals 4 & 8 will activate relay 1 for its programmed
strike time. This is where the postal switch is prewired.

7

A switch closure across these terminals will activate relay 2 for its programmed strike
time or cause the system to dial a preprogrammed phone number. See 3.1.6.

All wiring to be performed in accordance with National Electric Code.

10 11 12 13 14

1

9

8

7

6

5

4

3

2

1862-010
Circuit Board

Field Wire Diagram - 1862-010 Control Board

Earth

Ground

1800-060-R-8-11