11 keypad function, 12 star (*) key function, 13 automatic hang-up function – DoorKing 1803 Entry System User Manual

Page 31

Advertising
background image

3.1.11 Keypad

Function

This programming sequence sets the function of the 0 through 9, and the # keys on the keypad
during conversation. The keys can be set to hang-up the entry system when they are pressed during
conversation, or they can be programmed to DTMF tone out during conversation. The later may be
desirable if the entry system is used with an auto-attendant type telephone system where the caller is
prompted to enter numbers from a touch-tone telephone. HINT: If DTMF tones are required, program
the # or * key to hang-up the system.

Factory setting = 0 for all numbers (hang-up).

1.

Press *26 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the desired key number _ then press * (beep).

3.

Press 0* (beep) for hang-up, or press 1* (beep) for touch-tone.

4.

Repeat steps 2 and 3 to program other keys.

5.

Press 0# TOGETHER to end this programming step (beeeeeep).

3.1.12 Star (*) Key Function

This programming sequence sets the function of the * key on the keypad during conversation. This
key can be set to hang-up the entry system when pressed during conversation, or it can be
programmed to touch-tone out during conversation.

Factory setting = 0 (hang-up).

1.

Press *27 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Press 0* (beep) for hang-up, or press 1* (beep) for touch-tone.

3.

Press 0# TOGETHER to end this programming step (beeeeeep).

3.1.13 Automatic Hang-up Function

This programming sequence determines when the phone system will automatically hang itself up
after a predetermined time of inactivity. You can program the system to not hang-up (0), to hang-up
after 5 sec of dial-tone (1), to hang-up after 15 sec of silence (2) or to hang-up after either 5 sec of
dial-tone or 15 sec of silence (3). NOTE: This programming function is available on REV G
boards or higher only.

Factory setting = 1 (hang-up after 5 sec of dial-tone).

1.

Press *40 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the hang-up code desired _ then press * (beep).

3.

Press 0# TOGETHER to end this programming step (beeeeeep).

Code Function

0 No

hang-up.

1

Hang-up after 5 sec. of dial-tone (Factory setting).

2

Hang-up after 15 sec. of silence.

3

Hang-up after 5 sec. of dial-tone OR 15 sec. of silence.

1800-060-R-8-11

Page

31

Advertising