DIGIT SELECT KEY
VALUE SELECT KEY
MENU KEY
00000
RS485 full or half duplex
00000
Meter recognition character
and start & stop character
00000
RS232 RTS type
00000
Carriage return (and LF)
00000
Data sent via communications
(if BCD, only 1 item allowed)
Ser 3
Serial interface setup
(only enabled if communica-
tions board installed)
0
Full duplex
1
Half duplex
0
" * " , none, CR
1
Spl, none, CR
2
" * " , Spl, Spl
3
Spl , Spl, Spl
0
Nonlatching RTS
1
Latching RTS
0
Only at end of all items
1
At end of each item
0
All active items sent
1
Item #1 only
2
Item #2 only (if active)
3
Item #3 only (if active)
4
Peak value
5
All active items + peak
1.5
SERIAL INTERFACE SETUP - COUNTER ONLY
00000
RS485 full or half duplex
00000
Special start &stop character
00000
RS232 RTS type
00000
Carriage return (and LF, if
selected)
00000
Data sent via communications
(if BCD, only 1 item allowed)
Ser 3
Serial interface setup
(only enabled if communica-
tions board installed)
0
Full duplex
1
Half duplex
0
Normal format, continuous
1
Special start and stop
0
Nonlatching RTS
1
Latching RTS
0
Only at end of all items
1
At end of each item
(If alarm, only at end)
0
Net and Gross
1
Net only
2
Gross only
3
Peak only (net or gross)
4
Net & gross & peak
1.6
SERIAL INTERFACE SETUP - SCALE METER ONLY