• RGA Indicator – Indicates red when the RGA (Resin Gel Alarm) is active,
a whistle will also sound.
Figure 3 – Control Panel
Machine Operation:
Before the system can be used the slide-valve must be moved to the on position
and the E-Stop must be released. When air is initially supplied all controls should
automatically reset to their non-operational state.
The various operational modes are described in the following sub-sections.
Emergency Stop – When the E-Stop has been activated, the machine will enter
a safe state. If the machine is injecting or recirculating, the E-Stop is equivalent
to pressing the stop button.
NOTE: Residual pressures may remain in the fluid sections of the system,
even though the E-Stop has been activated.