Magnum Venus Plastech INNOVATOR PRO 5000 (8003) User Manual
Page 29

MAGNUM VENUS PLASTECH
Innovator Pro Manual
29
Control Box User Connections - Side:
Signal connections and an indicator are located on the side of the control
enclosure, as illustrated in figure 8. They are as follows:
• Catalyst Overpressure Indicator – When this turns
red, it indicates there is a catalyst over-pressure state.
• Turbo Autosprue (TAS) – Use this to connect a TAS
(or similar) valve to the machine. The pilot signal will
become pressurized when inject mode is active.
• Signal Connector (PPVS) – Connect a pneumatic PV
sensor (PPVS) here to automatically control the
system during an injection. The user can also connect
a “Hold” or “Pause” signal to the machine if required.
When this signal is leaked in injection mode, the
machine pump will stop running and the inject gun will
close. When the signal is blocked the machine will
begin to run again after a user configurable delay. DO
NOT SUPPLY AIR TO THIS CONNECTION.
• Remote Stop – Connect a remote stop signal here.
This function works similarly to the stop button on the
control panel.
Figure 8 – Control Box Side
Connections