Using pliers, compress the Ball Stop and remove from the Foot Valve. Remove the Foot Valve Spring and
the Chrome Ball.
•
Caution: If only using the -SK Seal Kit, the Chrome Ball must be reused. Do not drop or dent this
ball as it will be permanently damaged and must be replaced. (FIG 3.91)