Install the Foot Valve assembly and the Collar. Then install the Hex Nuts onto the Cylinder Tie Rods. (FIG
6.33)
•
Note: Before tightening the Hex Nuts, check the orientation of the inlet port on the Foot Valve
assembly making sure it is in the correct position.
•
Caution: Do not overtighten the Hex Nuts.
FIG 6.33
Place 1-2 drops of thread lock on the Piston Body threads and Install the Rod Adapter assembly onto the
Piston Rod. (FIG 6.34)
FIG 6.34
The rebuilt Fluid Section is place back on the system.