Remove packing set – Magnum Venus Plastech Pro Series VPRO-45220 22:1 & 7:1 User Manual

Page 27

Advertising
background image

VPRO-45220 Series Resin Pump Manual

Rev. 11/2013

Page | 27

Remove Packing Set:

1. Place the pump in a vise by clamping onto the bottom slave arm. Be sure the opening at

the bottom of the center section is clear of the vise.

NOTE: To remove packing set you will use one set of the pack

ing removal tools “clamshells”

(45052-1). Each set of clamshells consists of two pieces of metal bent in a U-shape.

2. Remove the black plastic plugs on the side of the pump body.

3. Be sure the pump is set to mid-stroke.

NOTE: You should be able to access the hex screw and hex nut through the holes in the
pump head. If the pump is not at mid-stroke, connect and slowly increase air to the
pump until the pump is at mid-stroke. Be sure you have a second air hose connected to
the elbow on the shift block assembly (VPRO-2000). Then disconnect the air.

WARNING: Always disconnect the air when instructed to do so to prevent injuring
yourself and damaging the equipment.

4. Remove the upper slave arm from the pump by removing the hex cap screw which

secures the slave ar

m to the pump’s center section. Use two socket wrenches to remove

the hex screw. Use one wrench to hold the lock nut in position while using the other
wrench to remove the hex screw.

5. Move the pump to the top of the stroke by hand or reconnect the air to the pump. Be

sure you have a second air hose connected to the elbow on the shift block assembly.

DANGER: Never insert fingers or tools into the pump cavity when air is connected to the
pump. Serious injury or amputations may occur.

6. Slowly increase the air pressure until the pump reaches the top of the stroke, and then

shut off the air.

7. Disconnect the air.

WARNING: For your protection, always disconnect the air when instructed to do so.

8. Insert the clamshells (45052-1) around the piston rod. Insert the bottoms of the

clamshells between the piston rod and the center section. Center the tops under the hex
screw on either side of the piston rod.

9. Reconnect the air to the pump.

DANGER: Never insert fingers or tools into the pump cavity when air is connected to the
pump. Serious injury or amputation may occur.

10. Slowly increase the air pressure until the hole for the hex screw appears then shut off

the air.

11. Disconnect the air.

Advertising