Set The Packing Set:

1. Prime the Pro pump fluid section.

2. Close the gun-head.

3. SLOWLY increase the pump pressure to 60 psi.

4. Keep the pump stalled for 5 to 15 minutes to allow the packing set to set.

5. Decrease the pump pressure to the desired operating pressure. Now you are ready to

connect, prime and pressurize the catalyst pump for operation.