5 inserting panel air filters, 6 checking the suction turbine, 7 checking the filter system for leaks – Minuteman KS 28 G (6403.xx) User Manual

Page 56: Maintenance and service

Advertising
background image

56

Maintenance and Service

5.10.5 Inserting panel air filters
1. Insert the thoroughly cleaned or new

panel air filter (Fig.

24/5) from the

correct side in the filter support
frame.

Pay attention to the labeling on
the side of the panel air filter
(Fig.

24/5)!

2. Replace the filter cover (Fig.

24/8).

3. Close the bottom filter cover locks:

Pivot the hinged locks (Fig.

24/6)

over the edge of the filter cover
(Fig.

24/8).

4. Close the top filter cover locks:

Screw the knurled screws (Fig.

24/1)

on the threaded pins (Fig.

24/4).

5. Close the hood (Fig.

24/7) so that it

audibly locks.

5.10.6 Checking the suction turbine
1. Switch the machine on,

refer to Section 3.3.1.

2. Clean a dusty surface for test pur-

poses, refer to Section 3.3.4.

3. Switch the machine off,

refer to Section 3.3.5.

4. Remove the dirt hopper,

refer to Section 5.9.1.

5. Check whether dust has accumulat-

ed on the inner side of the panel air
filter (Fig.

24/5).

6. If you have the impression that the

suction turbine does not work or dust
escapes from the machine, contact a
Minuteman service center.

Do not open the hood
(Fig.

24/7) when the engine is

running. Risk of injury through
belt drive and rotating fan
(Fig.

24/3)!

5.10.7 Checking the filter system for

leaks

Do not open the hood
(Fig.

24/7) when the engine is

running. Risk of injury through
belt drive and rotating fan
(Fig.

24/3)!

1. When the engine is switched off,

hood (Fig.

24/7) is open and filter

cover (Fig.

24/8) removed, check

whether dust escapes at the edges
of the panel air filter (Fig.

24/5).

2. If this is the case, check the sealing

strips (Fig.

24/2), refer to Sec-

tion 5.10.4 and replace, if necessary.

3. Check the panel air filter (Fig.

24/5)

and replace, if necessary. The frame
of the panel air filter (Fig.

24/5) must

not be twisted nor show signs of
damage. Ensure that the panel air fil-
ter (Fig.

24/5) has been inserted true

to side, refer to Section 5.10.5.

4. Repeat this test a certain time after

cleaning. If dust continues to escape
at the edges of the panel air filter
(Fig.

24/5), contact a Minuteman

service center.

Advertising
This manual is related to the following products: