PASCO PS-2205 Dual Load Cell Amplifier User Manual

Page 3

Advertising
background image

®

Model No.PS-2205

Setup

3

Xplorer and Xplorer GLX Setup

If you will be using an Xplorer or Xplorer GLX in logging mode (not connected to a
computer), connect the Dual Load Cell Amplifier to the Xplorer or Xplorer GLX, turn
the interface on, and press

to begin data collection.

SPARK Setup

If the SPARK Science Learning System (SLS) is off, press and hold the power
button on the bottom to turn it on and then wait for the SPARK to boot up. The
screen will show a message to plug in a sensor.

Connect the PASPORT sensor to either of the ports on the top of the SPARK. The
screen will show the list of quantities measured by the connected sensor.

Graph Display (default)

To open a graph display, touch any quantity in the list and then touch SHOW to open
PAGE 1. Touch the right arrow next to PAGE 1 to go to the next display (digits).
Touch the Start button to begin collecting data.

Select a Display

To set up a particular display (e.g., digits display), touch BUILD. Touch a quantity
from the list, and then touch one of the display icons. Touch OK to open the display,
and then touch the Start button to begin collecting data.

Measurement Alignment

When you are using multiple Load Cells, you may find that their readings differ
slightly when they are measuring the same thing. Before putting the Load Cells into a
bridge, truss, or other structure, press the “TARE” button on the side of the Dual Load
Cell Amplifier to “zero” the reading of each of the Load Cells.

No calibration should be necessary for the PASCO Load Cells connected to the Dual
Load Cell Amplifier. The following description outlines the procedure for a one point
simultaneous calibration using DataStudio.

Start button

See the User’s Guides for
the Xplorer GLX or the
SPARK Science Learning
System for calibration
instructions.