PASCO PS-2201 Load Cell, 5 N User Manual

Load cell, 5 n, Introduction, About the load cell

Advertising
background image

I n s t r u c t i o n S h e e t

012-11097A

PASCO Structures System

Load Cell, 5 N

PS-2201

800-772-8700

www.pasco.com

®

*012-11097*

Recommended Equipment

Load Cell Amplifier (PS-2198) or Dual Load Cell
Amplifier (PS-2205)

PASPORT Interface or SPARK SLS

Related Equipment

Complete Structures Set (ME-6989)

Truss Set (ME-6990)

Bridge Set (ME-6991)

Advanced Structures Set (ME-6992)

Load Cell & Amplifier Set (PS-2199)

See www.pasco.com for details about PASPORT equipment and PASCO
Structures System parts and sets.

Introduction

The Load Cell, 5 N is designed to work with the PASCO Struc-
tures System. When connected to a PASCO interface through the
PS-2198 Load Cell Amplifier or PS-2205 Dual Load Cell Ampli-

fier, the Load Cell can measure compression and tension forces
in any component of the PASCO Structures System.

For example, the PASCO Structures System includes the
ME-6987 Flat Structures Members, ME-6990 Truss Set,
ME-6991 Bridge Set, and the ME-6992 Advanced Structures Set.

About the Load Cell

The PS-2201 Load Cell measures forces ranging from -5 N to
+5 N and is wired with a male 6-pin mini-DIN connector for
plugging into a Load Cell Amplifier.

Figure 1: The 5N Load Cell has a semi-transparent case

The PS-2198 Load Cell Amplifier supports up to six Load Cells.
The PS-2205 Dual Load Cell Amplifier supports two Load Cells.
The PS-2199 Load Cell and Amplifier Set includes one Load
Cell Amplifier and four 100 N Load Cells.

Adding Load Cells

To measure the compression and tension forces in individual
members, add load cells to any PASCO Structure. Replace a
beam with two shorter beams and a load cell.

#5 beam = load cell + two #3 beams

#4 beam = load cell + two #2 beams

#3 beam = load cell + two #1 beams

5 N Load Cell

Advertising