PASCO PK-9023 EQUIPOTENTIAL AND FIELD MAPPER User Manual
Page 8

scientific
4
012-04346B
arrow. Repeat the action of pivoting and touching with
the front lead until the potential reading in a given
direction is highest. Draw a new arrow. Repeat the
action of putting the ground lead at the tip (head) of
each new arrow and finding the direction in which the
potential difference is highest. Eventually , the arrows
drawn in this manner will form a field line. Return to the
dipole and select a new point at which to place the
voltmeter's ground lead. Again probe with the other lead
until the direction of highest potential difference is
found. Draw an arrow from the ground lead to the other
lead, and repeat the process until a new field line is
drawn. Continue selecting new points and drawing field
lines around the original dipole (see Figure 6).
Figure 8
Figure 6 (Example of 3 field lines between unlike dipoles)
Figure 7
Area to probe in order to
find highest potential
difference
Ground lead for
voltmeter
Tape
Pushpin
Electrode to voltage
source (battery or
power supply)
Conductive
paper
Dipole
Dipole
1st line
2nd line
3rd line