ADC Soneplex P-61-743 User Manual

Page 11

Advertising
background image

ADCP-61-743

• Issue 3 • September 2004

Page 11

© 2004, ADC Telecommunications, Inc.

4 FRONT PANEL OPERATION

All controls and indicators of the RTAU including the jack accesses for a selected DS1 signal
are located on the front panel (Figure 3). The controls and indicators are described in Table 2.

Table 2. RTAU Front Panel Description

INDICATOR

COLOR

DESCRIPTION

STATUS

Red

Module failure.

Yellow

LED

test.

Green

Module operating normally.

B8ZS / AMI

Green

Indicates that the user has selected B8ZS line code for the bipolar
interface.

Yellow

Indicates that the user has selected AMI line code for the bipolar
interface.

Off

Indicates that the user has selected the internal signal monitor
generator at the RTAU.

Intrusive Test

Yellow

LED test.

Green

Indicates that the selected test mode of the RTAU is intrusive.

Off

No intrusive testing in progress.

SWITCH

DESCRIPTION

LINE CODE

This is a pushbutton switch that toggles the DS1 interface between B8ZS, AMI, or
the internal signal monitor generator at the RTAU. When B8ZS has been selected,
the B8ZS/AMI LED will turn green; when AMI has been selected, the B8ZS/AMI
LED will turn yellow; when the internal signal monitor generator at the RTAU is
selected, the B8ZS/AMI LED will turn off. Using this switch overrides the Craft
Interface RTAU Line Code field setting.

BIPOLAR
ACCESS JACKS


DESCRIPTION

DS1 RX

Bantam jack connection from DS1 receive to test equipment. Bipolar DS1 signals
from external test equipment can be applied to the RX jack for testing.

DS1 TX

Bantam jack connection from DS1 transmit to test equipment. Bipolar DS1 signals
from external test equipment can be applied to the TX jack for testing.

Note: The DS1 RX and DS1 TX jacks may be used with 22 AWG Plastic Insulated
Cable (PIC) up to 655 feet in length. Access for drop or insert of DS1 signals
towards the network (DS3 interface) or toward the customer (DS1 distribution
modules) for monitoring and intrusive testing is configured through the Craft
Interface or the TL1 interface.