6 tl1 commands, Figure 16. loopf and loope – ADC Soneplex P-61-743 User Manual

Page 28

Advertising
background image

ADCP-61-743

• Issue 3 • September 2004

Page 28

 2004, ADC Telecommunications, Inc.

DS3 MUX

RTAU

A

B

A

B

EQUIPMENT (E)

[NETWORK]

FACILITY (F)

[CUSTOMER]

CIRCUIT

UNDER TEST

SIGNAL

PRESENCE
DETECTOR

DS3 MUX

RTAU

EQUIPMENT (E)

[NETWORK]

FACILITY (F)

[CUSTOMER]

CIRCUIT

UNDER TEST

SIGNAL

PRESENCE
DETECTOR

11872-B

QRS

LOOPE

LOOPF

QRS

Figure 16. LOOPF and LOOPE

RTAU SETUP AND CONTROL


EQUIPMENT SETUP
===============
Current User : CRAFT Test Circuit: 1-2
Line Code : INTERNAL Mode : SPLTE

SIGNAL GENERATOR SETUP
======================
Pattern Type : QRS #: --------------------------------
Frame Format : ESF
Loop Code : NONE #: ----------------

BIT ERROR SETUP Error Counts Status Elapsed Time
=============== ============ ====== ============
Error Count : 0 Data : F Sync: * ES :
Error Rate : OFF BPV : P Sync: * EFS:
Error Locn : N/A Frame: RAI :
CRC:
COFA

Test Timeout : 60 Measurement : START WAITING ON SYNC
In Minutes
Press CONTROL-A For Assistance

Figure 17. RTAU Setup and Control Screen (Starting a Measurement)

6 TL1

COMMANDS

The TL1 commands shown in Table 4 that are used for the RTAU are defined in Bellcore
requirement GR-000834-CORE. For more information about TL1 commands, refer to the
Soneplex System Operation and Maintenance Manual listed under Related Publications at the
beginning of this manual.

Advertising