ADCP-61-743

• Issue 3 • September 2004

Page 17

© 2004, ADC Telecommunications, Inc.

Table 3. RTAU Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

EQUIPMENT SETUP FIELDS, continued

Mode

Toggle

OVERVIEW: Valid access modes and the resulting

configurations are shown in Figure 8 (RTAU Test

Configuration Block Diagram), Figure 9 (MONF and

MONE), Figure 10 (SPLTB and SLPTA), Figure 11

(Typical Round-Robin Test Configuration), Figure 12

(Typical End Test Configuration), Figure 13 (SPLTF

and SLPTE), Figure 14 (Typical Point-to-Point Test

Configuration), Figure 15 (SPLTFL and SPLTEL),

and Figure 16 (LOOPF and LOOPE). In addition,

when the Mode field change is saved by pressing the

Enter or Return key, the MPU or SCU will instruct

the DS3 MUX to drop and insert the selected circuit.

DISABLE

DISABLE

When DISABLE is selected, no monitor or split

access can take place. Setting the Mode field to

DISABLE also stops any measurement in

progress, as if the Measurement field (described

below) had been set to STOP. The tested circuit

will also be restored to normal operation.

MONE

Non-intrusive

monitor access to the A pair.

MONF

Non-intrusive

monitor access to the B pair.

SPLTA

SPLTA mode indicates a split in the A

transmission path with a Test Signal Generator

(TSG) connected in the F direction, and a Signal

Presence Detector (SPD) connected to the signal

from the E direction.

SPLTB

SPLTB mode indicates a split in the B

transmission path with a TSG connected in the E

direction and an SPD connected to the signal from

the F direction.

SPLTE

SPLTE mode indicates a split in both the A and B

transmission paths. An SPD is connected to the line

incoming from the E direction and a TSG is

connected to the line outgoing to the E direction. The

line outgoing in the F direction is connected to a

QRSS source and the line incoming from the E

direction is terminated by the nominal characteristic

impedance of the line.

SPLTF

SPLTF indicates a split in both the A and B

transmission paths with a TSG connected to the line

outgoing to the F direction and an SPD connected to

the line incoming from the F direction. The line

outgoing in the E direction is connected to a QRSS

source and the line incoming from the E direction is

terminated by the nominal characteristic impedance

of the line.

(continued)