ADCP-61-743

• Issue 3 • September 2004

Page 22

 2004, ADC Telecommunications, Inc.

Table 3. RTAU Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

BIT ERROR SETUP FIELDS

OVERVIEW: Bit errors can be injected by the RTAU using the Bit Error Set Up fields. These sections are display-only fields that are

only displayed when the line code setting is INTERNAL. The Status field always shows the current status if the line code is

INTERNAL, but the Error Counts and Elapsed Time fields only show a value when a measurement is being made.

Error Count

Input

Range of 0 to 1544

Select either Error Count or Error Rate for bit

error setup. Both cannot be set at the same time.

If single errors or a burst of errors is desired, set

the Error Count field to the number of errors to

insert. If the Error Count field is set, the

number of errors will be transmitted each time

the Enter key is pressed.

0

Error Rate

Toggle

OFF, 1E-3, 1E-4,

1E-5, 1E-6, 1E-7

Select either Error Count or Error Rate for bit

error setup. Both cannot be set at the same time.

If a steady error rate is desired, set the Error

Rate field which indicates the rate bit or frame

errors are injected.

OFF

Error Locn

Toggle

OVERVIEW: The Error Location field must be

set to either PAYLOAD or FBE if the count or

rate field is set. Pressing the Enter or Return

key will cause the RTAU to send the errors.

NONE

NONE

Indicates count is 0 and rate is off.

PAYLOAD

Bit errors are injected.

FBE

Frame Bit Error. Frame errors are injected.

Error Counts Data

Display

only

None

Eight-digit counter or blank.

Blank

Error Counts BPV

Display

only

None

Eight-digit counter or blank.

Blank

Error Counts Frame

Display

only

None

Eight-digit counter or blank.

Blank

Error Counts CRC

Display

only

None

Eight-digit counter or blank.

Blank

Error Counts COFA

Display

only

None

Eight-digit counter or blank.

Blank

Status F Sync

Display

only

None

* or blank

Blank

Status P Sync

Display

only

None

* or blank

Blank

Status RAI

Display

only

None

* or blank

Blank

(continued)