ADC Soneplex P-61-743 User Manual

Page 29

Advertising
background image

ADCP-61-743

• Issue 3 • September 2004

Page 29

© 2004, ADC Telecommunications, Inc.

Table 4. TL1 Commands Used for the RTAU

COMMAND

DESCRIPTION

CHG-ACCMD-T1

Change Access Mode T1

CHG-LPBK-T1

Change Loopback T1

CHG-TSTSIG-T1

Change Test Signal T1

CONN-TACC-T1

Connect Test Access T1

DISC-MEAS Disconnect

Measurement

DISC-TACC

Disconnect Test Access Metallic/Digital

DISC-TSTSIG Disconnect Test Signal

MEAS-SIG-T1

Measure Signal T1

REPT-RSLT Report

Result

TST-INSERRBITS

Test Insert Error Bits

7 SPECIFICATIONS

The technical specifications for the RTAU modules are given in Table 5.

Table 5. RTAU Specifications

PARAMETER

SPECIFICATION

REMARKS

Input Power

Input Current (Max.)

175 mA at

–

48 Volts

Input Current (Nominal)

100 mA at

–

48 Volts

Input Voltage (Nominal)

–48 Vdc

Input Voltage Range

–42 to –60 Vdc

Power Consumption /
Dissipation (Max.)

8.2 watts

DS1 Jack Access

Electrical Interface

Bipolar

Termination

100 ohms nominal

± 5%

Jack Type

Bantam

Line Code

AMI or B8ZS

Controlled by front panel switch

Line Rate

1.544 Mbps ± 130 ppm max.

Dimensions

Height

× Width × Depth

9.5

Ч 9.9 Ч 1.0 inches

(24.1

Ч 25.1 Ч 2.5 cm)

Weight

12 oz. (.34 kg)

Environment

Operating Temperature

–40

° to 149° F (–40° to 65° C)

Storage Temperature

–40

° to 158° F (–40° to 70° C)

Relative Humidity (Operating)

5% to 95%

No condensation

Altitude (Operating
or Non-operating)

–1,312 to + 14,764 ft.
(–

400 to +4,500 m)

Advertising