4. Clean the individual parts with a deter­

gent solution and a soft brush. If neces­

sary, soak in a warm detergent solution.

Clean the air hole (6e) thoroughly.

6e

5. Rinse all parts with clean water and dry.

6. Fit the steam nozzle (6d) and frothing

tube (6c) back into the metal sleeve.

1

2

6d

6c

7. Twist the steam nozzle clockwise until

the marks are aligned.

8. Attach the milk frother to the steam

valve. Check that the red mark on the

steam valve is covered.

¡

Risk of scalding

Only use the appliance when the milk froth­

er (6) is completely assembled and i tted.

Cleaning the brewing unit

Clean the brewing unit regularly.

To pre­clean the brewing unit automatically:

Press the service button (12) briel y. The

appliance will rinse if coffee was dispensed

previously. It then switches off.

In addition to the automatic cleaning pro­

gramme, the brewing unit (5a) should be

removed regularly for cleaning (

Figure E at

the beginning of the instructions).

1. Press the power on/off switch

O / I (9) to

switch off the appliance. All lights go off.

2. Open the door (5b) to the brewing unit.

3. Slide the red lock (5d) on the brewing

unit completely to the left.

4. Press the red pushbutton (5c), grasp the

brewing unit by the recessed grips and

withdraw it from the appliance.

5. Rinse the brewing unit (5a) thoroughly

under running water.