TES501.. 08/2011

en

Specially developed and suitable descal-

ing and cleaning tablets are available

from retailers or customer service.

Order number Retailer

Customer

service

Cleaning

tablets

TCZ6001

310575

Descaling

tablets

TCZ6002

310967

Important: If there is a water ilter in the

water tank (16), it must be removed before

starting the service programme.

To start the service programme, press and

hold the service button (12) for at least

5 seconds.

Information: The service button (12) lash­

es while the programme is running.

LED

H

lights up.

● Empty the drip tray (8) and reinsert it.

The appliance rinses twice.

LED

G

lights up.

● Open the drawer (4).

● Drop a Bosch cleaning tablet into the

drawer (4) and close it.

● Press the start button (10).

LED

D

lights up.

● Fill the empty water tank (16) with luke­

warm water up to the

0.5l mark and then

dissolve two Bosch descaling tablets in

this water.

● Press the start button (10).

The service programme will now run for

approximately 10 minutes.

LED

h

lights up.

● Place a container with a capacity of at

least 0.5 litres under the milk frother

outlet (6).

● Pull out the milk frother (6)

to open it.

The service programme will now run for

approximately 12 minutes.

LED

D

lights up.

● Rinse the water tank (16) and reill it with

fresh water up to the

max mark.

● Press the start button (10).

The service programme will now run for

approximately 30 seconds and rinse the

appliance.

LED

h

lights up.

● Push the milk frother (6) in to close it.

The service programme will now run for

approximately 8 minutes.

LED

H

lights up.

● Empty the drip tray (8) and reinsert it.

If you are using a ilter, reinsert it now.

The appliance has been cleaned, descaled

and is ready for use again.