Simple troubleshooting

Problem

Cause

Remedy

Coffee is too “bitter”.

The grind setting is too ine

or the pre­ground coffee is

too ine.

Adjust the grinding unit to

a coarser setting or use

coarser pre­ground coffee.

Unsuitable type of coffee.

Change the type of coffee.

The water ilter does not

stay in position in the water

tank (16).

The water ilter is not itted

correctly.

Firmly press the water ilter

straight down into the tank

connection.

The coffee grounds are not

compact and are too wet.

The grind setting is too

ine or too coarse, or not

enough ground coffee has

been used.

Adjust the grinding unit to

a coarser or iner setting,

or use 2 level measuring

spoons of ground coffee.

LED

I

lashes.

Brewing unit (5) is soiled.

Cleaning the brewing

unit (5).

Too much pre­ground cof­

fee in the brewing unit (5).

Clean the brewing unit (5)

(Put in no more than 2

level measuring spoons of

ground coffee).

The brewing unit mecha­

nism is stiff.

Remove the brewing unit

and treat with a special

grease intended for this

purpose (order no. 311368),

see “Maintenance and daily

cleaning”.

Coffee or milk froth quality

varies widely.

Build­up of limescale in the

appliance.

Descale the appliance with

two descaling tablets as de­

scribed in the instructions.

Water dripped onto the in­

ner loor of the appliance

when the drip tray (8) was

removed.

Drip tray (8) removed too

soon.

Wait a few seconds after

the last drink was dis­

pensed before removing the

drip tray (8).

LED

I

lights up.

Brewing unit (5) is missing

or has not been detected.

Switch off the appliance

with the brewing unit (5) in

place, wait three seconds

and switch on the appliance

again.