enFORCE

Operation Manual

PAGE 4 - 10

Chapter 4: System Setup and Wiring

System Parameter 00, D-No. 08 – HOME SENSOR/BANK1 signal is normally “BANK 1”.

To enable Output Banks 2 & 3, set Parameter 00-08 to ‘2’. (See Page 6-22)
If using the CYCLE OK signal, BANK 1 output is not available in Bank 1.


The BUSY signal is normally used to operate the brake. When changing Banks, the
meaning of the BUSY signal will change when a bank other than Bank 1 is selected.
(See Section 4.14 for Brake Operation)

BANK1 BANK0

OUT DATA Signal

Name

Description

OFF OFF

OUT DATA0 BYPASS

Output when press is in BYPASS

OUT DATA1 ORG OK

Output after home position has been defined.

OUT DATA2 POS STOP

Output when the cylinder is stopped in home position.

OUT DATA3 BUSY

Output while operating.

OUT DATA4 READY

Output when the system is READY to operate.

OUT DATA5 ABNORMAL

Output when an Abnormal condition occurs.

OUT DATA6 ACCEPT

Output when the system has halted without failure.

OUT DATA7 REJECT

Output when the system has halted with failure.

OUT DATA8 ADVANCED

Output when the press has reached target load or distance.

OUT DATA9 TIMING

Output timing signal. Used when Par. 00, D-No. 0A is set.

OUT DATA10 CYCLE OK/BANK1

Output when the press reaches the distance set in Param.
00, D-No. 0A (1~9) / Output echo of Bank Select 1 Input.

OUT DATA11 BANK0

Output echo of BANK Select 0 Input.

OFF ON

OUT DATA0

OUT DATA1

OUT DATA2

OUT DATA3 WORK

SELECT

4

Output echo of selected Input.

OUT DATA4 WORK

SELECT

3

OUT DATA5 WORK

SELECT

2

OUT DATA6 WORK

SELECT

1

OUT DATA7 WORK

SELECT

0

OUT DATA8

OUT DATA9

OUT DATA10 BANK1

Output echo of BANK Select 1 Input.

OUT DATA11 BANK0

Output echo of BANK Select 0 Input.

ON OFF

OUT DATA0 LOAD_LOW

Output on a Low Load Reject.

OUT DATA1 LOAD_HIGH

Output on a High Load Reject.

OUT DATA2 Rt2_LOW

Output on a Rate 2 Low Reject

OUT DATA3 Rt2_HIGH

Output on a Rate 2 High Reject

OUT DATA4 Rt1_LOW

Output on a Rate 1 Low Reject

Both ON:
1

ST

Zone Reject

OUT DATA5 Rt1_HIGH

Output on a Rate 1 High Reject

OUT DATA6 DIS_LOW

Output on a Low Distance Reject

OUT DATA7 DIS_HIGH

Output on a High Distance Reject.

OUT DATA8

OUT DATA9

OUT DATA10 BANK1

Output echo of Bank Select 1 Input.

OUT DATA11 BANK0

Output echo of Bank Select 0 Input.

ON ON

OUT DATA0

OUT DATA1

OUT DATA2

OUT DATA3

OUT DATA4

OUT DATA5

OUT DATA6

OUT DATA7

OUT DATA8

OUT DATA9

OUT DATA10 BANK1

Output echo of Bank Select 1 Input

OUT DATA11 BANK0

Output echo of Bank Select 0 Input.