FEC DSP1500 (SAN3) User Manual

Page 19

Advertising
background image

enFORCE

Operation Manual

PAGE 4 - 19

Chapter 4: System Setup and Wiring

4.8.2 Special Configuration Settings (DIP Switch 1~3)

1 ON:

CAL/Zero acceptance window = +/-10% of full scale load.

OFF: CAL/Zero acceptance window = +/-4% of full scale load. (Default)
2 ON:

Parameter changes made by communicating are not saved on EEPROM.

OFF:

Parameter changes made by communicating are saved on EEPROM. (Default)

3 ON: Ramp Up / Down Disabled

The speeding up and slowing down is done rapidly.

It is used to gain cycle time, etc., however, the burden on the gear will be greater.

OFF: Ramp Up / Down Enabled

(Default)

The speeding up and slowing down is done slowly.

The diagrams below show the effects of the DIP switch 3 setting as seen on an
oscilloscope for a DPT-021R1 press (top 2 diagrams) and a DPT-201R3 press (bottom 2
diagrams). Both presses were set up to run Distance Control at maximum speed with the
brake disabled (always disengaged).































If not used, set DIP switches number 1 thru 3 in the OFF position.

SAN Unit must be powered off and on again for switch changes to take effect.


Advance

Return

470ms

30ms

470ms

470ms

Advance

Return

190ms

30ms

190ms

85ms

Advance

Return

488ms

14ms

488ms

456ms

Advance

Return

96ms

14ms

96ms

90ms

DIP Switch 3 OFF

DIP Switch 3 ON

DIP Switch 3 OFF

DIP Switch 3 ON

DPT-021R1

DPT-201R3