Operation – General Technologies CT8030 Dual Display Professional Automotive Digital Multimeter User Manual

Page 2

Advertising
background image

Audible Continuity Tester

Audible threshold : between 10Ω, and 60Ω.

Response time:

200μs.

O

2

Sensor Tester

Application :

For O

2

Sensor dynamic test

Main Display :

Symbolic waveform display of O

2

Sensor

dynamic output.

Mini display :

Cross count per second parameter.

A beep sound will alert the user on each

significant cross count edge

Sweep Rate :

10 per second.

Alternator tester

Application :

For quick go / no go test on alternators

Threshold :

The display indicates "bad" and the

beeper turns on when the measured

ripple voltage is greater than 0.45VAC.

Fault Code Detector

Application :

For blink type fault code detection

Display :

The display indicates a symbolic pulse and

the beeper turns on when the blink code

pulse is detected.

Threshold :

4.5VDC with selectable positive or negative

pulse trigger (by ±Trigger button).

DTC (Diagnostic Trouble Code) Decoder

Application :

A replacement of the Impulse Counter Scan

Tool as specified in the Mercedes-Benz

Diagnostic Trouble Code Reference Guide

to scan the DTC Code readout automatically

on the Mercedes-Benz car series.

4. OPERATION

4.1 Instrument Description

1- LCD Display: 4-3/4digit 40000 count 4 digits 9999 count dual display.

2-

: Pushbutton, press momentarily to select trigger levels,

or press and hold for 1 second to toggle between positive and

negative trigger slopes.

3-

: Pushbutton to select Auto/Manual ranging in most

functions, or number of cylinders in Dwell function.

4-

: Pushbutton to select relative zero and relative

percentage change.

5-

: Pushbutton. Press momentarily to turn on the display

backlight, or press and hold for 1 second to recall stored data.

6- Rotary Switch: Turns the power ON and OFF and selects

measuring functions.

7- COM Input Socket: Common (Ground Reference) Input

connector for all functions except TACH function.

4.3 Measurement Procedures

CAUTION: Maximum Input Voltage is 750Vrms,do not exceed

this rating to avoid personal injuries or damage to the

instrument. The FUNCTION switch should be set to

the range you want to test before the operation.

CAUTION: Always ensure that the correct terminals are used for

the type of measurement to be made. Avoid making

connections to “live” circuits whenever possible.When

making current measurements ensure that the circuit

is not “live” before opening it in order to connect the

test leads.

4.3.1 DC/AC Voltage Measurement

4.2 Display Description

15.

: These annunciators indicate trigger level status.

16.

: These annunciators indicate positive (

) or negative

(

) Trigger Slope is selected.

17.

: Negative polarity symbol.

18.

: annunciator indicates direct current (DC) is selected.

annunciator indicates alternating current (AC) is selected.

19. DATA : Main digital readings of data being measured.

20.

: This annunciator indicates Auto Power Off is enabled.

21.

: This annunciator indicates Autoranging.

22. +

-

: Low Battery alert, replace the battery as soon as possible

to ensure accuracy.

23.

: This annunciator indicates the Alternator tester function

is selected.

24. : This annunciator indicates data HOLD function is activated.

25.

: This annunciator indicates the Record function is activated.

26.

: This annunciator indicates the Crest function is activated.

27.

: This annunciator indicates the Fault Code Detector

function is activated.

28.

: This annunciators indicate MAX (Maximum), MIN

(Minimum), MAX-MIN (Maximum minus Minimum), or AVG

(Average) reading is being displayed.

29. DATA : Secondary display for Dual Display data.

30. kHz : These annunciators indicate the function being selected

and/or the appropriate measurement units.

31.

: Analog bar graph with overload flag, polarity and scale.

8-

: Input Socket for all functions except Current and TACH

functions.

9- mA A/RPM : Input Jack ( ) for current function, and

ground reference (

) input Jack for RPM function.

10- RPM : INPUT JACK ( ) FOR RPM FUNCTION

11-

: Pushbutton. Press momentarily to activate hold, or

press and hold for 1 second to store the data displayed for

later recall

12-

: Pushbutton. press momentarily to select secondary

functions, or press and hold for 1 second to erase all stored

datas

13-

: Pushbutton. press momentarily to toggle between

40,000 and 4000 counts modes, or press and hold for 1

second to activate record function

14-

: Pushbutton. press momentarily to toggle between

RPM

4

and

RPM

2

in RPM function, or press and hold for 1

second to activate Crest function

Set rotary switch to

position.

Default at DC. Press SELECT button momentarily to select AC,

and press again to select Hz if required.

Insert red (

) test lead into

jack and black (

) test lead into

COM input jack.

Connect test leads to voltage source and observe the digital display

for the readout.

Set rotary switch to

position for voltage application below

0.4V with similar operation procedures.

Refer (4-2) for enabling dual display RPM function.

Hz Function: 4 trigger levels selectable through the LEVEL push

button for advanced applications in this function. Also refer to section

5.8 of this manuals for more details.

4.3.2 DUAL DISPLAY RPM Function

Set the meter to the corresponding primary function. See note

below for function availability.

Press

button to toggle to

RPM

2

for 2-stroke and DIS

engine, or to RPM

4

for 4-stroke engine.

Insert output plug of inductive pick up with the positive (red) into

RPM jack and the negative (black) into the RPM

jack.

Clamp the inductive pick up to a spark plug wire with the arrow

sign facing the spark plug. Make sure that the pick up jaws are

completely closed.

Observe the secondary digital display for RPM readings.

Page 2

Page 3

Advertising