General Technologies CT8030 Dual Display Professional Automotive Digital Multimeter User Manual

Page 3

Advertising
background image

Note: 1- This function is available to primary functions: DCV, ACV,

Hz, Dwell, Fuel injection detector, & Duty cycle.

2- When trigger level selection is required for advanced

applications, use main display RPM function. See (4.3.6)

for more details.

4.3.3 TEMPERATURE Function

4.3.4

DIODE TEST function

Connect the test leads as shown and observe the digital display.

Default at

Ω

. Press SELECT button momentarily to select

Continuity function.

A continuous beep tone indicates a complete wire. This is useful

for checking wiring connections and operation of switches.

4.3.6 RPM function (main display)

Set rotary switch to

.

Default at 4 cylinders (

). Press cylinder (RANGE) button

momentarily to display the cylinder setting on the secondary

display, and press momentarily again within one second to select

the number of cylinders from 1 through 12 to match the engine

under test.

Insert red ( ) test lead into jack and black ( ) test lead into

COM input jack.

Connect the test leads as shown and observe the digital display.

Press SELECT button momentarily to display DWELL reading in

terms of percentage if required.

Refer (4-2) for convenient dual display RPM function.

Adjust the dwell angle according to the procedures outlined in your

vehicle service manual.

Note: 1- Re-check the timing whenever the dwell angle has been

adjusted.

2- 4 trigger levels selectable through LEVEL push button for

advanced applications in this function. Also refer (5-8) for

more details.

4.3.8

FUEL INJECTION DETECTOR Function

Temperature Probe

Set rotary switch to

position

Press SELECT button momentarily two times to select temperature

function.

Without any temperature probe plugged into the input terminals

(detect automatically by the meter), the secondary digital display
displays the meter internal temperature reading in °C & °F
alternatively.

Insert the banana plug type-K temperature bead probe (standard

accessory) with correct polarities. Positive ( ) plugs into
jack where negative ( ) plugs into COM input jack. You can also
use a plug adapter (optional accessory) with banana pins to type-
K socket to connect other standard type-K mini plug temperature
probes.

Touch the end of the thermo probe to the measurement surface

and observe the digital display with °C in the main display, and °F
in the second display.

Set rotary switch to

.

Insert red ( ) test lead into jack and black ( ) test lead into

COM input jack.

Connect the test leads as shown and observe the digital display.

Normal forward voltage drop (forward biased) for a good silicon

diode is between 0.400V to 0.900V. A reading higher than that

indicates a leaky diode (defective). A zero reading indicates

a shorted diode (defective). An ‘OL’ indicates an open diode

(defective).

Reverse the test leads connections (reverse biased) across the

diode.

The digital display shows ‘OL’ if the diode is good. Any other

readings indicate the diode is resistive or shorted (defective).

4.3.5

Ω

RESISTANCE, CONTINUITY Functions

CAUTION: Maximum Input Voltage for this function is 600 Vrms

do not exceed this rating to avoid personal injuries

or damage to the instrument. Also ensure there is no

power applied to the component or circuit and all

capacitors are discharged.

Set rotary switch to

Ω

Insert red ( ) test lead into jack and black (

) test lead into

COM input jack

Set rotary switch to

.

Press

RPM

4 2

button to toggle to

RPM

2

for 2-stroke and DIS

engine, or to

RPM

4

for 4-stroke engine.

Insert output plug of inductive pick up with the positive (red) into

RPM jack and the negative (black) into the RPM

jack.

Clamp the inductive pick up to a spark plug wire with the arrow

sign pointing the spark plug. Make sure that the pick up jaws are

completely closed.

Observe the digital display for RPM readings.

Note: 4 trigger levels selectable through LEVEL push button, for

advanced applications in this function. Also refer (5.8) for

more details.

4.3.7 DWELL Function

Set rotary switch to -ms.

Insert red ( ) test lead into jack and black ( ) test lead into

COM input jack.

Connect the test leads as shown and observe the digital display.

Press SELECT button momentarily to display ms reading in terms

of percentage (%) if required.

Refer (4-2) for convenient dual display RPM function.

Note: 1. This -ms function applies to both Port Fuel Injectors (PFI)

which operate with a single on time pulse and Throttle Body

Injectors (TBI) which operate with twin pulses.

2. 4 trigger levels selectable through LEVEL push button for

advanced applications in this function. Also refer (5.8) for

more details.

3. The fuel injection frequency can be displayed on the

secondary display by pressing the

button.